Hi

Contact us for more special prices!

Get a free product quote

Please provide your phone number and email address, and we’ll get in touch with you promptly within one business day to resolve your issue as soon as possible.

Contact Info

Service Hotline:

86-311-86032617

Company email:

info@tonhe.com.cn

Headquarters address:

No. 350, Lijiang Road, Shijiazhuang High-tech Zone

JLKZQ
+
  • JLKZQ

JLKZQ

The JLKZQ module developed by Shijiazhuang Tonghe Electronic Technology Co., Ltd. fully accounts for the diverse applications in power systems. Its data acquisition unit adopts a modular design, while the CPU processing unit is equipped with a high-speed computing chip, ensuring rapid measurement of AC voltage, AC current, active power, power factor, and other parameters. The module also controls external electrical actuators according to preset strategies, thereby enabling automatic transfer of the AC incoming line.


Keywords:


Share now

  • Description
  • Parameters
  • Application
  • Product Info
  • Product Introduction

    The JLKZQ module developed by Shijiazhuang Tonghe Electronic Technology Co., Ltd. fully accounts for the diverse applications in power systems. Its data acquisition unit adopts a modular design, while the CPU processing unit employs a high-speed computing chip, ensuring rapid measurement of AC voltage, AC current, active power, power factor, and other parameters. The module also controls external electrical actuators according to preset strategies, thereby enabling automatic transfer of the AC incoming line.

    Product Features

    • Measure AC voltage, current, frequency, active power, reactive power, and power factor across three phases.
    •11-channel discrete output control, capable of commanding the electric operating mechanism to perform AC incoming line automatic transfer.
    •Status monitoring of 16-channel digital input signals
    • Supports RS485 communication

  • Technical indicators

    AC voltage accuracy

    Three-phase (A, B, C), measurement range 0–300 VAC (phase voltage)
    Measurement error: ±1% within the 170–265 VAC range.

    AC current accuracy

    Channel 3, measurement range 0–5 A
    Measurement error: ±1% within the 20%–100% range.

    Digital output

    Channel 11, relay output, normally open contact.
    Rating: AC 250 V / 1 A, DC 30 V / 0.5 A, DC 220 V / 0.1 A

    Digital Input

    Route 16, requires a passive dry contact.

    RS485 interface

    RS485 interface

    Power supply

    Power input: 88–286 VDC; power consumption ≤ 10 W.

    Size

    116*202*62.5mm (front view: height*width*depth)

    Interface Definition

    Digital Input SI 1

    1# Digital input signal, connected to the open/close status of QF1, the incoming line switch.

    Digital Input SI 2

    2# Digital input signal, connected to the trip status of QF1’s incoming line switch.

    Digital Input SI 3

    3# Digital input signal, connected to the open/close status of QF2’s incoming line switch.

    Digital Input SI 4

    4# Digital input signal, connected to the trip status of QF2’s incoming line switch.

    Digital Input SI 5

    5# Digital input signal, connected to the open/close status of the QF3 incoming line switch.

    Digital Input SI 6

    6# Digital input signal, connected to the trip status of QF3 incoming circuit breaker.

    Digital Input SI 7

    7# Digital input signal, connected to the open/close status of QF4’s incoming line switch.

    Digital Input SI 8

    8# Digital input signal, connected to the trip status of the QF4 incoming circuit breaker.

    Digital Input SI 9

    9# Digital input signal, connected to the open/close status of QF5’s incoming line switch.

    Digital Input SI 10

    10# Digital input signal, connected to the trip status of QF5’s incoming line switch.

    Digital Input SI 11

    11# Digital signal output, 1# AC incoming line leakage current detection (open‑circuit output)

    Digital Input SI 12

    12# Digital signal output, 2# AC incoming line leakage current detection (open contact)

    Digital Input SI 13

    13# Digital signal output, 0# AC incoming line leakage current detection (open‑circuit output)

    Digital Input SI 14

    14# Digital signal output, 1# AC bus voltage anomaly detection (open contact)

    Digital Input SI 15

    15# Digital signal output, 2# AC bus voltage anomaly detection (open contact)

    Digital Input SI 16

    Backup

    COM

    Common terminal for discrete input signals

    K1, C1, K2

    Control QF1 switching

    K3, C2, K4

    Control QF2 switching

    K5, C3, K6

    Control QF3 switching

    K7, C4, K8

    Control QF4 switching

    K9, C5, K10

    Control QF5 switching

    SYS

    System failure

    AC Channel 0 Voltage VAC0

    Three-phase AC voltage measurement interface

    AC Circuit 1 Voltage VAC1

    Three-phase AC voltage measurement interface

    AC voltage, 2 channels, VAC2

    Three-phase AC voltage measurement interface

    0# AC busbar current ACI

    Three-phase AC current measurement interface

    1# AC busbar current ACI

    Three-phase AC current measurement interface

    2# AC busbar current ACI

    Three-phase AC current measurement interface

    RS485 interface

    RS485 communication interface, providing two ports for convenient wiring.

    Power Supply

    Power supply

Get a free product quote

Please provide your phone number and email address, and we’ll get in touch with you promptly within one business day to resolve your issue as soon as possible.

Related products

The H series is manufactured using thick-film hybrid integration technology. Its enclosure features a fully sealed metal structure, and the interior is filled with inert gas.
Learn more Learn more
This series of fire‑fighting power supplies is a core power‑supply device independently developed by our company, specifically designed to ensure reliable electrical power during emergencies such as fires. It truly serves as a guardian of the “lifeline.”
Learn more Learn more
This series of fire‑fighting power supplies is a core power‑supply device independently developed by our company, specifically designed to ensure reliable electrical power during emergencies such as fires. It truly serves as a guardian of the “lifeline.”
Learn more Learn more
For complex environments such as tunnel lighting, outdoor road lighting, and marine lighting—where stable illumination is of critical importance—our company has independently developed a new generation of intelligent lighting power‑supply products.
Learn more Learn more
< 1 >